Test
Report
UMGENI WATER, HEAD OFFICE
:
P.O.
Box
9,
Pietermaritzburg 3200
•
310 Burger
Street
,
Pietermaritzburg 3201 South
Africa
Telephone
:
(033)
341243/1344/1013
•
Fax:
(033) 341
1
501
Personal Information (PI) requested in this form is mandatory for operational and administrative processes, and to comply with regulatory requirements. Umgeni Water
will take reasonable steps to ensure that the Personal Informationcollected on this form is processed responsibly, kept safeand confidential, and does not unjustifiably
infringe your privacy. This is in compliance to the Protection of Personal Information Act No. 4 of 2013.
This Certificate ofAnalysismay only bereproduced in
full
unless
written
approval isgiven by the Manager, Laboratory
Services
CUSTOMER INFORMATION
Laboratory Customer Code
529
Name
Erna Kruger / Michael Malinga
Company Name
Mahlathini Development Foundation
Postal Address
2 Foresters Lane, Pietermaritzburg, 3201
Telephone Number
0828732289
Email Address
info@mahlathini.org; michael.malinga@mahlathini.org
Date Sample/s Taken
26-04-23
LABORATORY TESTING INFORMATION
Sample Matrix
Water
Sample Condition on Receipt
& Handling
4 samples were received in good condition. The samples were logged and submitted immediately to
the laboratory for analysis.
Date Sample/s Received
28-04-23
Date Testing Commenced
28-04-23
Date Testing Completed
05-05-23
Test Report Date
08-05-23
Results Interpretation
Explanatory Information
1.These results are subject to change and must not be considered as final, unless this test report is
signed by appropriate laboratory technical signatories. Should any results change, you will be
informed thereof, before issuing the final test report.
2.Results and or determinands/parameters marked with an asterix (*) are not SANAS accredited and
are not included in the SANAS Schedule of Accreditation for this laboratory.
3.Results pertain to the sample/s as taken by you and in the condition received by this laboratory.
4.All laboratory testing is done at the Head Office laboratory. Any sub-contracted testing will be
clearly marked on the test report.
5.Information pertaining to the testing methods, is obtainable from the laboratory.
6.For SANS 241 conformance testing, acid extractable metals are analysed. All other results are
reported as total unless indicated otherwise.
7.In assessing the conformity of test results to the specification on the test report, Umgeni Water
Laboratory Services shall report test results using thefollowing decision rule: “A binary rule
(pass/fail) decision rule using the guard band as per ILAC G8_09_2019; at a 95% Confidence
Interval, shall apply to all reported results”. Therefore, the probability of reporting a false rejection of
a test result against a specification is at <2.5% Confidence Interval. When a statement of conformity
is not required, test results are reported as an absolute value.
8.Statement of Conformity of results: Based on the laboratory’s decision rule, all results that are
depicted in bold font shall be deemed as non-compliant to the defined specification per
determinand/parameter, where applicable.
9.Statements 7 and 8 (above) apply to accredited methods results only.
10.Samples are held for 7 working days, where possible, after the provision of results and unless
results are queried with a formal request for re-testing, it is implied that all test results are accepted
and the sample/s will be discarded.
11.Opinions and Interpretation of results are based on the test results obtained from the sample/s
tested and falls outside the scope of accreditation.
Test Report Number: 2023-0320Page Number: 1 of 6

Test
Report
UMGENI WATER, HEAD OFFICE
:
P.O.
Box
9,
Pietermaritzburg 3200
•
310 Burger
Street
,
Pietermaritzburg 3201 South
Africa
Telephone
:
(033)
341243/1344/1013
•
Fax:
(033) 341
1
501
Personal Information (PI) requested in this form is mandatory for operational and administrative processes, and to comply with regulatory requirements. Umgeni Water
will take reasonable steps to ensure that the Personal Informationcollected on this form is processed responsibly, kept safeand confidential, and does not unjustifiably
infringe your privacy. This is in compliance to the Protection of Personal Information Act No. 4 of 2013.
This Certificate ofAnalysismay only bereproduced in
full
unless
written
approval isgiven by the Manager, Laboratory
Services
Laboratory Comment: Sample 2 days old when testing commenced. pH, Alkalinity, E. coli, Total Coliforms and
Heterotrophic Plate counts may be affected. Treat results with reserve.
Sample ID
2047799
Uncertainty
of
Measurement
(UoM)
SANS 241:2015
Drinking Water
Standard Limits
Required
SANS
241:2015
Drinking Water
Classification
Sample Description
Stulwane Bergville
MDF Spring 1
Method
Number
Determinands
Units
Results
1a
Alkalinity*
mg CaCO3/L
19.3
±3.6%
no limit
-
7
Appearance*
Descriptive
Clear Colourless
not applicable
no limit
-
30
Calcium*
mg Ca/L
<5.00
±4.3%
no limit
-
5a
Chloride (soluble)*
mg Cl/L
<1.00
±2.6%
≤300
aesthetic
19
Colour
mg Pt-Co/L
<1.00
±7.3%
≤15
aesthetic
Calculation
Combined Nitrate +
Nitrite Ratio*
-
0.20
not applicable
≤1
acute health
21
Conductivity@ 25°C
mS/m
3.27
±1.9%
≤170
aesthetic
121
E.coli
MPN/100mL
54
±8%
0
acute health
94
Fluoride
µg F/L
<100
±5.3%
≤1500
chronic health
30
Iron
mg Fe/L
<0.02
±3.2%
≤0.3
aesthetic
≤2.0
chronic health
27
Total Hardness*
mg CaCO3/L
<33.3
not applicable
no limit
-
80
Heterotrophic plate
count @ 37°C
CFU/mL
>1000
±20%
≤1000
operational
30
Potassium*
mg K/L
<5.00
±6.4%
no limit
-
30
Magnesium*
mg Mg/L
<5.00
±3.2%
no limit
-
30
Manganese
mg Mn/L
<0.01
±2.8%
≤0.1
aesthetic
≤0.4
chronic health
30
Sodium*
mg Na/L
<5.00
±3.3%
≤200
aesthetic
5a
Nitrite (soluble)*
mg N/L
<0.10
±4.2%
≤0.9
acute health
5a
Nitrate (soluble)*
mg N/L
1.03
±6%
≤11
acute health
7
Odour*
Descriptive
Nil
not applicable
Inoffensive
aesthetic
46
pH
pH Units
5.97
±0.57%
≥5 to ≤ 9.7
operational
5a
Sulphate (soluble)*
mg SO4/L
<1.00
±2.9%
≤250
aesthetic
≤500
acute health
151
Total Organic Carbon
mg C/L
<1.00
±4.3%
≤10
chronic health
121
Total Coliforms
MPN/100mL
1203
±6%
≤10
operational
69
Turbidity
NTU
0.7
±2%
≤1
operational
≤5
aesthetic
Test Report Number: 2023-0320Page Number: 2 of 6

Test
Report
UMGENI WATER, HEAD OFFICE
:
P.O.
Box
9,
Pietermaritzburg 3200
•
310 Burger
Street
,
Pietermaritzburg 3201 South
Africa
Telephone
:
(033)
341243/1344/1013
•
Fax:
(033) 341
1
501
Personal Information (PI) requested in this form is mandatory for operational and administrative processes, and to comply with regulatory requirements. Umgeni Water
will take reasonable steps to ensure that the Personal Informationcollected on this form is processed responsibly, kept safeand confidential, and does not unjustifiably
infringe your privacy. This is in compliance to the Protection of Personal Information Act No. 4 of 2013.
This Certificate ofAnalysismay only bereproduced in
full
unless
written
approval isgiven by the Manager, Laboratory
Services
Laboratory Comment: Sample 2 days old when testing commenced. pH, Alkalinity, E. coli, Total Coliforms and
Heterotrophic Plate counts may be affected. Treat results with reserve.
Sample ID
2047800
Uncertainty
of
Measurement
(UoM)
SANS 241:2015
Drinking Water
Standard Limits
Required
SANS
241:2015
Drinking Water
Classification
Sample Description
Stulwane Bergville
Municipal Spring
Method
Number
Determinands
Units
Results
1a
Alkalinity*
mg CaCO3/L
119
±3.6%
no limit
-
7
Appearance*
Descriptive
Clear Colourless
not applicable
no limit
-
30
Calcium*
mg Ca/L
27.8
±4.3%
no limit
-
5a
Chloride (soluble)*
mg Cl/L
<1.00
±2.6%
≤300
aesthetic
19
Colour
mg Pt-Co/L
<1.00
±7.3%
≤15
aesthetic
Calculation
Combined Nitrate +
Nitrite Ratio*
-
0.12
not applicable
≤1
acute health
21
Conductivity@ 25°C
mS/m
23.7
±1.9%
≤170
aesthetic
121
E.coli
MPN/100mL
0
±8%
0
acute health
94
Fluoride
µg F/L
118
±5.3%
≤1500
chronic health
30
Iron
mg Fe/L
0.12
±3.2%
≤0.3
aesthetic
≤2.0
chronic health
27
Total Hardness*
mg CaCO3/L
95.2
not applicable
no limit
-
80
Heterotrophic plate
count @ 37°C
CFU/mL
>1000
±20%
≤1000
operational
30
Potassium*
mg K/L
<5.00
±6.4%
no limit
-
30
Magnesium*
mg Mg/L
6.18
±3.2%
no limit
-
30
Manganese
mg Mn/L
<0.01
±2.8%
≤0.1
aesthetic
≤0.4
chronic health
30
Sodium*
mg Na/L
15.3
±3.3%
≤200
aesthetic
5a
Nitrite (soluble)*
mg N/L
<0.10
±4.2%
≤0.9
acute health
5a
Nitrate (soluble)*
mg N/L
0.10
±6%
≤11
acute health
7
Odour*
Descriptive
Nil
not applicable
Inoffensive
aesthetic
46
pH
pH Units
6.59
±0.57%
≥5 to ≤ 9.7
operational
5a
Sulphate (soluble)*
mg SO4/L
2.08
±2.9%
≤250
aesthetic
≤500
acute health
151
Total Organic Carbon
mg C/L
<1.00
±4.3%
≤10
chronic health
121
Total Coliforms
MPN/100mL
1553
±6%
≤10
operational
69
Turbidity
NTU
3.5
±2%
≤1
operational
≤5
aesthetic
Test Report Number: 2023-0320Page Number: 3 of 6

Test
Report
UMGENI WATER, HEAD OFFICE
:
P.O.
Box
9,
Pietermaritzburg 3200
•
310 Burger
Street
,
Pietermaritzburg 3201 South
Africa
Telephone
:
(033)
341243/1344/1013
•
Fax:
(033) 341
1
501
Personal Information (PI) requested in this form is mandatory for operational and administrative processes, and to comply with regulatory requirements. Umgeni Water
will take reasonable steps to ensure that the Personal Informationcollected on this form is processed responsibly, kept safeand confidential, and does not unjustifiably
infringe your privacy. This is in compliance to the Protection of Personal Information Act No. 4 of 2013.
This Certificate ofAnalysismay only bereproduced in
full
unless
written
approval isgiven by the Manager, Laboratory
Services
Laboratory Comment: Sample 2 days old when testing commenced. pH, Alkalinity, E. coli, Total Coliforms and
Heterotrophic Plate counts may be affected. Treat results with reserve.
Sample ID
2047801
Uncertainty
of
Measurement
(UoM)
SANS 241:2015
Drinking Water
Standard Limits
Required
SANS
241:2015
Drinking Water
Classification
Sample Description
Stulwane Bergville
Unprotected Spring
Method
Number
Determinands
Units
Results
1a
Alkalinity*
mg CaCO3/L
33.0
±3.6%
no limit
-
7
Appearance*
Descriptive
Clear Brown
not applicable
no limit
-
30
Calcium*
mg Ca/L
<5.00
±4.3%
no limit
-
5a
Chloride (soluble)*
mg Cl/L
<1.00
±2.6%
≤300
aesthetic
19
Colour
mg Pt-Co/L
6.50
±7.3%
≤15
aesthetic
Calculation
Combined Nitrate +
Nitrite Ratio*
-
<0.12
not applicable
≤1
acute health
21
Conductivity@ 25°C
mS/m
5.25
±1.9%
≤170
aesthetic
121
E.coli
MPN/100mL
28
±8%
0
acute health
94
Fluoride
µg F/L
<100
±5.3%
≤1500
chronic health
30
Iron
mg Fe/L
0.25
±3.2%
≤0.3
aesthetic
≤2.0
chronic health
27
Total Hardness*
mg CaCO3/L
<33.3
not applicable
no limit
-
80
Heterotrophic plate
count @ 37°C
CFU/mL
448
±20%
≤1000
operational
30
Potassium*
mg K/L
<5.00
±6.4%
no limit
-
30
Magnesium*
mg Mg/L
<5.00
±3.2%
no limit
-
30
Manganese
mg Mn/L
0.01
±2.8%
≤0.1
aesthetic
≤0.4
chronic health
30
Sodium*
mg Na/L
<5.00
±3.3%
≤200
aesthetic
5a
Nitrite (soluble)*
mg N/L
<0.10
±4.2%
≤0.9
acute health
5a
Nitrate (soluble)*
mg N/L
<0.10
±6%
≤11
acute health
7
Odour*
Descriptive
Nil
not applicable
Inoffensive
aesthetic
46
pH
pH Units
7.06
±0.57%
≥5 to ≤ 9.7
operational
5a
Sulphate (soluble)*
mg SO4/L
<1.00
±2.9%
≤250
aesthetic
≤500
acute health
151
Total Organic Carbon
mg C/L
<1.00
±4.3%
≤10
chronic health
121
Total Coliforms
MPN/100mL
2420
±6%
≤10
operational
69
Turbidity
NTU
27.4
±2%
≤1
operational
≤5
aesthetic
Test Report Number: 2023-0320Page Number: 4 of 6

Test
Report
UMGENI WATER, HEAD OFFICE
:
P.O.
Box
9,
Pietermaritzburg 3200
•
310 Burger
Street
,
Pietermaritzburg 3201 South
Africa
Telephone
:
(033)
341243/1344/1013
•
Fax:
(033) 341
1
501
Personal Information (PI) requested in this form is mandatory for operational and administrative processes, and to comply with regulatory requirements. Umgeni Water
will take reasonable steps to ensure that the Personal Informationcollected on this form is processed responsibly, kept safeand confidential, and does not unjustifiably
infringe your privacy. This is in compliance to the Protection of Personal Information Act No. 4 of 2013.
This Certificate ofAnalysismay only bereproduced in
full
unless
written
approval isgiven by the Manager, Laboratory
Services
Laboratory Comment: Sample 2 days old when testing commenced. pH, Alkalinity, E. coli, Total Coliforms and
Heterotrophic Plate counts may be affected. Treat results with reserve.
Sample ID
2047802
Uncertainty
of
Measurement
(UoM)
SANS 241:2015
Drinking Water
Standard Limits
Required
SANS
241:2015
Drinking Water
Classification
Sample Description
Vimbukhalo Municipal
Spring
Method
Number
Determinands
Units
Results
1a
Alkalinity*
mg CaCO3/L
40.4
±3.6%
no limit
-
7
Appearance*
Descriptive
Clear Brown
not applicable
no limit
-
30
Calcium*
mg Ca/L
7.92
±4.3%
no limit
-
5a
Chloride (soluble)*
mg Cl/L
1.90
±2.6%
≤300
aesthetic
19
Colour
mg Pt-Co/L
2.60
±7.3%
≤15
aesthetic
Calculation
Combined Nitrate +
Nitrite Ratio*
-
0.12
not applicable
≤1
acute health
21
Conductivity@ 25°C
mS/m
9.20
±1.9%
≤170
aesthetic
121
E.coli
MPN/100mL
12
±8%
0
acute health
94
Fluoride
µg F/L
125
±5.3%
≤1500
chronic health
30
Iron
mg Fe/L
0.20
±3.2%
≤0.3
aesthetic
≤2.0
chronic health
27
Total Hardness*
mg CaCO3/L
<40.6
not applicable
no limit
-
80
Heterotrophic plate
count @ 37°C
CFU/mL
296
±20%
≤1000
operational
30
Potassium*
mg K/L
<5.00
±6.4%
no limit
-
30
Magnesium*
mg Mg/L
<5.00
±3.2%
no limit
-
30
Manganese
mg Mn/L
<0.01
±2.8%
≤0.1
aesthetic
≤0.4
chronic health
30
Sodium*
mg Na/L
5.84
±3.3%
≤200
aesthetic
5a
Nitrite (soluble)*
mg N/L
<0.10
±4.2%
≤0.9
acute health
5a
Nitrate (soluble)*
mg N/L
0.13
±6%
≤11
acute health
7
Odour*
Descriptive
Nil
not applicable
Inoffensive
aesthetic
46
pH
pH Units
6.50
±0.57%
≥5 to ≤ 9.7
operational
5a
Sulphate (soluble)*
mg SO4/L
<1.00
±2.9%
≤250
aesthetic
≤500
acute health
151
Total Organic Carbon
mg C/L
<1.00
±4.3%
≤10
chronic health
121
Total Coliforms
MPN/100mL
2420
±6%
≤10
operational
69
Turbidity
NTU
17.7
±2%
≤1
operational
≤5
aesthetic
Test Report Number: 2023-0320Page Number: 5 of 6

Test
Report
UMGENI WATER, HEAD OFFICE
:
P.O.
Box
9,
Pietermaritzburg 3200
•
310 Burger
Street
,
Pietermaritzburg 3201 South
Africa
Telephone
:
(033)
341243/1344/1013
•
Fax:
(033) 341
1
501
Personal Information (PI) requested in this form is mandatory for operational and administrative processes, and to comply with regulatory requirements. Umgeni Water
will take reasonable steps to ensure that the Personal Informationcollected on this form is processed responsibly, kept safeand confidential, and does not unjustifiably
infringe your privacy. This is in compliance to the Protection of Personal Information Act No. 4 of 2013.
This Certificate ofAnalysismay only bereproduced in
full
unless
written
approval isgiven by the Manager, Laboratory
Services
LABORATORY TECHNICAL SIGNATORY RESPONSIBLE FOR REVIEW AND AUTHORIZATION OF THIS TEST REPORT
NAME
DESIGNATION
TECHNICAL SIGNATORY FOR METHODS
SIGNATURE
Mr TP Khumalo
Technical Supervisor Chemistry
All Chemistry test methods-excluding soils
Mrs ZP Sithole
Technical Supervisor Chemistry
1,19,21,30,46,59,69,94,102,154,162,178
Ms MT Zondi
Technical Supervisor Chemistry
45,151,157,158,168,169,171,177
Mr S Hadebe
Technical Supervisor Chemistry
164,165,166,167
Ms P Magebeni
Technical Supervisor Microbiology
80,82,83,85,121,176
Ms J Moodley
Technician Microbiology
80,176
Ms S Myeza
Technician Microbiology
85
Ms K Dlomo
Technical Supervisor Microbiology
121
Ms ZSN Mhlambi
Scientist Hydrobiology
77,78,103,104,105
Ms P Ndlovu
Technical Supervisor Hydrobiology
78, 176
Ms I Dusrath
Technician Hydrobiology
78,103,104,105
Mr N Jwara
Technician Hydrobiology
78
Test Report Number: 2023-0320Page Number: 6 of 6